Digital Activation of Independent Park Heater/Auxiliary Heater
Digital Activation of Independent Park Heater/Auxiliary Heater
Activation via telegrams on K-bus
Telegram sequence for auxiliary heater ON:
- The heating/air conditioning control unit recognises the need for heating and sends the AUXILIARY HEATER ON telegram to the independent park heater/auxiliary heater.
- The independent park heater/auxiliary heater sends the AUXILIARY HEATER ON
feedback to the heating/air conditioning control unit and starts up.
- If no feedback is received from the independent park heater/auxiliary heater, the AUXILIARY HEATER ON telegram is sent twice at an interval of 1 second. A corresponding fault code entry is made in the fault code memory if all 3 start attempts are unsuccessful.
Telegram sequence for auxiliary heater OFF:
- The heating/air conditioning control sends the AUXILIARY HEATER OFF
telegram to the independent park heater/auxiliary heater.
- The independent park heater/auxiliary heater sends the AUXILIARY HEATER OFF
feedback to the heating/air conditioning control unit and assumes after-run mode.
- If no feedback is received from the independent park heater/auxiliary heater, the AUXILIARY HEATER OFF telegram is sent twice at an interval of 1 second. A corresponding fault code entry is made in the fault code memory if all 3 stop attempts are unsuccessful.
Telegram sequence for independent park heating ON:
- The MID or on-board monitor sends the INDEPENDENT PARK HEATING ON telegram via IKE to the heating/air conditioning control unit
- The heating/air conditioning control sends the AUXILIARY HEATER ON
telegram to the independent park heater/auxiliary heater.
- The independent park heater/auxiliary heater sends the AUXILIARY HEATER ON
feedback to the heating/air conditioning control unit and starts up.
- The heating/air conditioning control unit receives the AUXILIARY HEATER ON
feedback from the independent park heater/auxiliary heater.
- If no feedback is received from the independent park heater/auxiliary heater, the AUXILIARY HEATER ON telegram is sent twice at an interval of 1 second. A corresponding fault code entry is made in the fault code memory if all 3 start attempts are unsuccessful.
Telegram sequence for independent park heating OFF:
- The MID or on-board monitor sends the INDEPENDENT PARK HEATING OFF telegram via IKE to the heating/air conditioning control unit
- The heating/air conditioning control sends the AUXILIARY HEATER OFF
telegram to the independent park heater/auxiliary heater.
- The independent park heater/auxiliary heater sends the AUXILIARY HEATER OFF
feedback to the heating/air conditioning control unit and assumes after-run mode.
- The heating/air conditioning control unit receives the AUXILIARY HEATER OFF
feedback from the independent park heater/auxiliary heater.
- If no feedback is received from the independent park heater/auxiliary heater, the AUXILIARY HEATER OFF telegram is sent twice at and interval of 1 second. A corresponding fault code entry is made in the fault code memory if all 3 stop attempts are unsuccessful.
Telegram sequence for Telestart:
- The wavetrap receives the telestart signal and converts the HF signal into an LF signal.
- The telestart receiver sends a signal to the independent park heater/auxiliary heater.
- The independent park heater/auxiliary heater sends the AUXILIARY HEATER ON
message to the heating/air conditioning control unit.
- The heating/air conditioning control unit sends AUXILIARY HEATER ON to the independent park heater/auxiliary heater.
- The independent park heater/auxiliary heater sends the AUXILIARY HEATER ON
feedback to the heating/air conditioning control unit and starts up.
- If no feedback is received from the independent park heater/auxiliary heater, the AUXILIARY HEATER ON telegram is sent twice at an interval of 1 second. A corresponding fault code entry is made in the fault code memory if all 3 start attempts are unsuccessful.
Telegram sequence in the event of faults in the independent park heater/auxiliary heater:
- The independent park heater/auxiliary heater sends a fault message AUXILIARY HEATER OFF
to the heating/air conditioning control unit.
- The heating/air conditioning control unit sends AUXILIARY HEATER ON to the independent park heater/auxiliary heater.
- The heating/air conditioning control unit waits for the reply AUXILIARY HEATER ON
from the independent park heater/auxiliary heater.
- The AUXILIARY HEATER OFF telegram is sent globally once the AUXILIARY HEATER OFF
feedback is received from the independent park heater/auxiliary heater.
- If the fault message AUXILIARY HEATER OFF
is sent repeatedly by the independent park heater/auxiliary heater, the AUXILIARY HEATER ON is sent twice at an interval of 1 second. A corresponding fault code entry is made in the fault code memory if all 3 start attempts are unsuccessful.
Telegram sequence in the event of fault lock-out in the independent park heater/auxiliary heater:
- The independent park heater/auxiliary heater sends a fault lock-out message AUXILIARY HEATER OFF
to the heating/air conditioning control unit.
- The BMW DIS Service Tester sends the CANCEL FAULT LOCK-OUT telegram to the independent park heater/auxiliary heater or the fuse for the voltage supply to the independent park heater/auxiliary heater is isolated for 10 seconds.