A11 Heating and A/C control module IHKR

Plug connector overview

NumberX-pinDescription
X183413Heating and A/C control module Plug connector 0
X61026Heating and A/C control module Plug connector 3
X61118Heating and A/C control module Plug connector 4
X181533Heating and A/C control module Plug connector 5

Pin assignments at plug connector 0 X18341

PinTypeDescription / Signal typeConnection /
Measuring notes
1APositive supply, magnetic clutchHigh pressure switch
   
2EVoltage supply terminal 30Fuse F11
   
3MGroundGround point
   

Pin assignments at plug connector 3 X610

PinTypeDescription / Signal typeConnection /
Measuring notes
1EVoltage supply, terminal 15Fuse F20
U-batt.  
2ECompressor switch-on signal from DMEDME control unitDDE control unit
   
3ASignal, A/C compressor to DMEDME control unitDDE control unit
   
4AStandby signal, air conditioning system to DMEDME control unit 728i,730i, 735i, 740iDDE control unit 725tds
  Connector for air conditioning 750i
5ARelay activation, rear window defoggerRear defogger relay
   
6ARelay activation, windscreen/spray jet heatingHeated front screen/washer jets relay
   
7 Not used 
   
8Aup to 08/1995 Not used as of 09/1995 Blower control voltageOutput stage
   
9 Not used 
   
10 Not used 
   
11 Not used 
   
12ESignal, switch off consumer loadGeneral module
   
13 Not used 
   
14AAuxiliary water pump activationAuxiliary water pump
   
15ARelay activation, blower unloader relayHeating blower relay
   
16 Not used 
   
17ARelay activation, auxiliary fan stage IAuxiliary fan stage 1 relay
   
18ENight light signalLight module
   
19E/AK-bus signal lineK-bus connector
   
20ALeft water valve activationWater valves, Left valve
   
21ARight water valve activationWater valves, Right valve
   
22 Not used 
   
23 Not used 
   
24 Not used 
   
25 Not used 
   
26 Not used 
   

Pin assignments at plug connector 4 X611

PinTypeDescription / Signal typeConnection /
Measuring notes
1AActuating signalFresh air flap motor
   
2AActuating signalFresh air flap motor
   
3AActuating signalFresh air flap motor
   
4AActuating signalFresh air flap motor
   
5 Not used 
   
6 Not used 
   
7 Not used 
   
8 Not used 
   
9 Not used 
   
10AActuating signalRight ventilation flap motor
   
11AActuating signalRight ventilation flap motor
   
12AActuating signalRight ventilation flap motor
   
13AActuating signalRight ventilation flap motor
   
14MComponent groundSensor
   
15ESensor signalEvaporator sensor
   
16ESensor signalRight heat exchanger sensor
   
17ESensor signalLeft heat exchanger sensor
   
18ESwitch-off signalMotor limit switch
   

Pin assignments at plug connector 5 X18153

PinTypeDescription / Signal typeConnection /
Measuring notes
1ASignal, independent heating ONup to 08/1995 Independent heating/ventilation control unit as of 09/1995 Receiver, independent heating
   
2AControl voltageIndependent heating relay
   
3EIndependent heating ON feedbackIndependent heating/ventilation control unit