A14 Independent park/auxiliary heating

Plug connector overview

NumberX-pin, colourDescription
X6422-pin, BlackPlug connector Independent park/auxiliary heating
X7646-pin, BlackPlug connector Independent park/auxiliary heating
X010112-pin, BlackPlug connector Flame monitor
X010122-pin, BlackPlug connector Circulation pump motor
X010132-pin, BlackPlug connector Combustion-air blower motor
X010142-pin, BlackPlug connector Heater plug

Pin assignments at plug connector X642

PinTypeDescription / Signal typeConnection /
Measuring notes
1ETerminal 30Fuse F47
   
2MGroundGround point
   

Pin assignments at plug connector X764

PinTypeDescription / Signal typeConnection /
Measuring notes
1ESignal, independent heating ONReceiver, independent heating M57 Heating and A/C control module
   
2E/ADiagnostic signal TXD X183Connector, TXD X183
   
3 Not used 
   
4ETelestart signalHeating and A/C control module
   
5 Not used 
   
6ASupply Metering pump (independent heating)Metering pump (independent heating)
   

Pin assignments at plug connector X01011

PinTypeDescription / Signal typeConnection /
Measuring notes
1ASupply Flame monitorFlame monitor
   
2ESignal Flame monitorFlame monitor
   

Pin assignments at plug connector X01012

PinTypeDescription / Signal typeConnection /
Measuring notes
1ASupply Circulation pump motorCirculation pump motor
   
2MGround Circulation pump motorCirculation pump motor
   

Pin assignments at plug connector X01013

PinTypeDescription / Signal typeConnection /
Measuring notes
1ASupply Combustion-air blower motorCombustion-air blower motor
   
2MGround Combustion-air blower motorCombustion-air blower motor
   

Pin assignments at plug connector X01014

PinTypeDescription / Signal typeConnection /
Measuring notes
1ASupply Heater plugHeater plug
   