A turbocharger with variable turbine geometry and without a wastegate is used for boost pressure control. It is operated by means of an adjustment lever on the turbine housing. The adjustment lever is connected by means of a control rod to the vacuum unit on the turbocharger such that the control rod is extended and retracted corresponding to the vacuum applied.
The pressure converter links the vacuum unit with the vacuum supply by means of hoses and, depending on the activation status, it switches a variable vacuum to the vacuum unit controlled by the DDE control unit. In this way, the control rod is set in the required position. The pressure converter is activated by a square-wave signal with duty factors (= variable pulse width) between 5 and 95 %.
Fault code 65 "turbocharger control" is stored in the event of impermissible control deviation or fault "short/open circuit in pressure converter activation".
Consequences:
Boost pressure control is also deactivated if following faults occur: