S2 Ignition switch

Plug connector overview

NumberX-pin, colourDescription
X3311-pin, blackPlug connector Ignition switch

Pin assignments at plug connector X33

PinTypeDescription / Signal typeConnection /
Measuring notes
1ASignal Terminal 15Unloader relay terminal 15
   
2AVoltage supply terminal RFuse Terminal R
   
3 Not used 
   
4 Not used 
   
5EVoltage supply terminal 30Cable shoe Fuse F16
   
6EVoltage supply terminal 30Cable shoe Output fuse F106
   
7EVoltage supply terminal 30Fuse F3
   
8ASignal, terminal 50Electronic immobilizer control unit (EWS) DME control unit
   
9AVoltage supply, terminal 15Fuse Terminal 15
   
10ASignal Terminal 15Output stage, rear compartment blower
   
11 Not used