A/C power output DDE 4.0

The A/C compressor is switched on and off by the DDE control unit. The DDE control unit receives a message from the heating and A/C control unit as to whether the air conditioning system button is pressed and whether the heating and A/C control unit is requesting that the compressor be switched on. If a request is received to switch on the A/C compressor, the DDE control unit checks whether conditions that do not permit the compressor to be switched on apply and sends a corresponding message back to the heating and air conditioning control unit. Switch-on of the A/C compressor is inhibited by the DDE control unit under following conditions:

Troubleshooting

The line between the DDE control unit and heating and air conditioning control unit is monitored for short-circuit and open circuit. Fault code 3515 ”A/C power output” is stored in the case of defect.