Data on working range and substitute value in event of cutout or K bus fault.
Temperature sensor  | 
	Working range  | 
	Substitute value  | 
Heat exchange sensor  | 
	5 °C ... 114 °C  | 
	55 °C  | 
Evaporator sensor  | 
	-10 °C ... 30 °C  | 
	0 °C  | 
Interior temperature sensor  | 
	10 °C ... 40 °C  | 
	20 °C  | 
Exterior temperature value  | 
	K-bus  | 
	0 °C  | 
Coolant temperature value  | 
	K-bus  | 
	100 °C  | 
Specified temperature  | 
	16 °C ... 32 °C  | 
	22 °C  | 
Data on resistance values at an ambient temperature of 25 °C and fault limits.
Temperature sensor  | 
	Resistance  | 
	Fault limit  | 
Heat exchange sensor  | 
	10 kOhm +/- 5%  | 
	Temperature > 125 °C  | 
Evaporator sensor  | 
	3 kOhm +/- 2%  | 
	Temperature > 85 °C or temperature =< -46 °C  | 
Interior temperature  | 
	10 kOhm +/- 2%  | 
	Temperature > 80 °C or temperature =< -46 °C  |