The BYTEFLIGHT bus system has a star-shaped structure. The individual satellites (= control units with/without sensors) are interconnected across a star coupler by means of fibre-optic cables. The star coupler in the BYTEFLIGHT bus system is the Safety and Gateway Module. There is a transmission and a reception module (transmitter and receiver) as a unit in each satellite for connecting to the BYTEFLIGHT bus. The unit has an integrated transmit and receive diode.
The procedure for the following fault code memory entries is shown below:
Two cases are distinguished:
The following Table 1 shows which control units generate a fault code memory entry if a transmitting control unit does not send a certain message. The first vertical column contains the transmitting control units (TCU); the first horizontal line contains the receiving control units (RCU).
Table 1:
|
RCU |
SBSL |
SBSR |
SFZ |
SGM |
TMFA |
TMBF |
SZL |
TCU |
|
|
|
|
|
|
|
|
SGM |
|
X |
X |
|
|
|
|
|
SBSL |
|
|
X |
X |
X |
X |
X |
X |
SBSR |
|
X |
|
X |
X |
X |
X |
X |
SFZ or TMFA or TMBF |
|
X |
X |
|
X |
|
|
|
Table 2:
|
RCU |
SBSL |
SBSR |
SFZ |
SGM |
TMFA |
TMBF |
SZL |
TCU = ? |
|
X |
X |
|
|
|
|
|
SBSL |
Satellite, B-pillar left |
SBSR |
Satellite, B-pillar right |
SFZ |
Satellite, vehicle centre |
SGM |
Safety and Gateway Module |
TMFA |
Door module, driver |
TMBF |
Door module, passenger |
SZL |
Steering column switch cluster |
All work on the airbags must be carried out with the battery disconnected!
Connect and disconnect all BYTEFLIGHT control units, sensors and generators only with the battery disconnected!
If a fibre-optic cable on the BYTEFLIGHT bus has to be repaired, it must be borne in mind that there may only be one join in a fibre-optic cable. If there is already a join due to a door connector, the fibre-optic cable must not be repaired. In the case of a defect, the fibre-optic cable must be replaced!