Picture signals CVBS and RGB

Recorded signal paths

The following signal paths can deviate from the voltage values. The sequence should, however, match at the marked positions.

Signal path CVBS signal

For the CVBS signal, the colour information of the colours green, red and blue is transmitted across a single cable. The signal path has three important points that are independent of the image transmitted at that moment. This is why these points are used for measurement

For measurement, the following voltage differences must be examined.

Difference

With adapter

Without adapter

Point 1, Point 2

0.4 V

0.8 V

Point 2, Point 3

0.3 V

0.6 V

GR_FBAS-DISPLUS

Signal path RGB signal

For the RGB signal, the picture information is transmitted across three cables separated by colour. Red, green and blue. The synchronisation of the RGB signal is implemented via the green signal. The signal path has points that are independent of the image shown. These points are used for measurement

For measurement, the following voltage differences must be examined.

Difference

With adapter

Without adapter

Point 1, Point 2

0.3 V

0.6 V

Point 2, Point 3

0.4 V

0.8 V

GR_RGB_2

Measurement with and without adapter

In the case of measurement without adapter, the second control unit (SG2) is disconnected. Upper circuit. For this measurement, the signal level is only measured via the resistance R. This is why a measurement without adapter leads to a double signal level.

In the case of measurement with adapter, the second control unit (SG2) remains connected. The signal level is then measured via the parallel circuit of resistances R and R2. Lower circuit.

GR_MIT_OHNE_ADAPTER