The Mechatronic (electronic module and hydraulic control unit) has various solenoid valves and electronic pressure control valves.
Functional description, see BMW Technology:
TIS -> Document -> SI Technology -> SBT Number
The solenoid valves are 3/2-way valves, i.e. valves with 3 connections and 2 switch positions.
The EDS convert electric current into a proportional hydraulic pressure and thus activate hydraulic valves with their corresponding switch elements.
Two types of electronic pressure actuators are fitted:
If the Mechatronic has to be replaced in the course of repairs, it must be labelled as a replacement Mechatronic using the service function ā€¯Mechatronic calibrationā€¯.
The service function must also be run after repair to individual electronic pressure actuators or of the electronic module. Here, the replaced electronic pressure actuators are marked in the control unit as exchange parts. If this designation is not carried out, the shift quality can be reduced significantly.
After replacement of the entire gearbox, the service function does not have to be run, as the gearbox is already fully calibrated on delivery.
In all cases, it is advisable to delete stored adaptation values.