Pin | Type | Description / Signal type | Connection / Measuring notes |
---|
1 | A | Signal, roller sun blind up | Motor, rear window roller sun blind |
| | |
2 | A | Signal, roller sun blind down | Motor, rear window roller sun blind |
| | |
3 | A | Signal, heat exchanger water valve, left | Water valves |
| | |
4 | A | Signal, heat exchanger water valve, right | Water valves |
| | |
5 | A | Signal, auxiliary water pump | Auxiliary water pump |
| | |
6 | A | Signal, refrigerant control valve | Control valve, refrigerant compressor |
| | |
7 | A | Signal, wiper park position heating | Relay, wiper park position heating |
| | |
8 | A | Voltage supply, AUC sensor | AUC sensor |
| | |
9 | E | Signal, AUC sensor | AUC sensor |
| | |
10 | E | Signal, refrigerant pressure sensor | Coolant pressure sensor |
| | |
11 | M | Ground, hazard warning/center lock button | Ground point |
| | |
12 | A | Signal, center lock released | Car access control unit |
| | |
13 | A | Signal, hazard warning | Light module |
| | |
14 | A/E | Bus signal, blower motor | Blower output stage |
| | |
15 | A/E | Signal, CAN-bus | CAN-bus connector |
| | |
16 | A/E | Signal, CAN-bus | CAN-bus connector |
| | |
17 | A | Voltage supply, AUC sensor heating | AUC sensor |
| | |
18 | M | Ground, AUC sensor | AUC sensor |
| | |
19 | A | Voltage supply, refrigerant pressure sensor | Coolant pressure sensor |
| | |
20 | M | Ground, refrigerant pressure sensor | Coolant pressure sensor |
| | |
21 | | Not used | |
| | |
22 | | Not used | |
| | |
23 | | Not used | |
| | |
24 | | Not used | |
| | |
25 | A | Signal, center lock locked | Car access control unit |
| | |
26 | A | Signal, hazard warning indicator | Light module |
| | |
Pin | Type | Description / Signal type | Connection / Measuring notes |
---|
1 | M | Ground, sensor system | Ground connector |
| | |
2 | E | Temperature signal, heat exchanger, right | Heat exchanger temperature sensor, right |
| | |
3 | | Not used | |
| | |
4 | | Not used | |
| | |
5 | A | Signal, fresh air flap actuator | Fresh air flap actuator |
| | |
6 | A | Signal, fresh air flap actuator | Fresh air flap actuator |
| | |
7 | E | Signal, temperature after evaporator | Evaporator temperature sensor |
| | |
8 | E | Temperature signal, heat exchanger, left | Heat exchanger temperature sensor, left |
| | |
9 | E | Temperature signal, ventilation | Ventilation temperature sensor unit |
| | |
10 | | Not used | |
| | |
11 | A | Signal, fresh air flap actuator | Fresh air flap actuator |
| | |
12 | A | Signal, fresh air flap actuator | Fresh air flap actuator |
| | |