The leak rates of the valves are determined in the leak test and stored in the CE control unit.
The maximum values for the leak rates are:
Leak rate |
Maximum value [mbar*l/s] |
1 Filling and pressure relief valves |
0.7 |
2 engine shutdown valve |
0.35 |
3 engine shutdown valve |
0.2 |
4 Pressure regulator |
0.04 |
5 Pressure regulator |
0.3 |
Values greater than the specified maximum values indicate a faulty valve.
Leak-tightness of the following valves:
- Valve for filling/extraction gaseous
Valve for filling/extraction liquefied
- Pressure relief valve
Check of the volume between filling / extraction valve gaseous and engine shutoff valve.
Check of the volume between engine shutoff valve and pressure regulator.
Check of the volume between pressure regulator and engine shutdown valve.