The events in the case of too many wakings are described below. In the event of a fault, all the measures serve to ensure the starting capability of the vehicle and for diagnosis if the fault has caused a flat battery.
Index |
Explanation |
Index |
Explanation |
---|---|---|---|
1 |
TerminalĀ R off: |
2 |
Consumer unit shutdown: 8 minutes after terminal R Off if the vehicle is not locked. |
3 |
Deactivation of terminal 30g |
4 |
The JBE sends the 'Power Down' command if the vehicle was wakened 10 times after deactivation of terminalĀ 30g. |
5 |
Reset of terminal 30g-f |
6 |
Deactivation of terminal 30g-f |
7 |
After terminal R Off, the vehicle is wakened too frequently: the number of wakings is stored in the energy history memory. |
8 |
Terminal R ON Bus communication is active. |
In the top example, only two authorised wakings are shown: