Test of injector return flow volume DDE6.0
Accessories required for the test:
	- Angle connector for injector return (1) with attached hose section
 
- Suitable measuring cap for diesel fuel
 
Procedure:
	- Pull off the return line at the injector to be tested
 
- Close the removed return line (2)
 
- Attach the angle connector with hose section (1) to the injector return; insert the hose in the measuring cap
 
- Run the engine (idle); measure the return flow volume
 
 
 
 
 
 
	- Connection at the return of the injector
 
- Cap for removed return line
 The test of the injector return volumes is only implemented for injectors with conventional solenoid valve technology. This test is not available for piezo injectors.