Number | X-pin, colour | Description |
---|---|---|
X610 | 26-pin, blue | Plug connector Heating/air conditioning system |
X4714 | 18-pin, blue | Plug connector Heating/air conditioning system |
Pin | Type | Description / Signal type | Connection / Measuring notes |
---|---|---|---|
1 | E | Terminal 30 | Fuse F39 |
2 | E | Terminal 15 | Fuse F22 |
3 | E | Terminal 58g | Light switch cluster |
4 | M | Ground | Ground connector |
5 | Not used | ||
6 | A | Signal, auxiliary water pump Not M54 | Auxiliary water pump |
7 | Not used | ||
8 | A | Compressor control | Control valve, refrigerant compressor |
9 | E/A | K-bus signal | K-bus connector |
10 | Not used | ||
11 | Not used | ||
12 | Not used | ||
13 | A | Signal, rear window defogger | Rear defogger relay |
14 | A | Signal, rear window defogger | Rear defogger relay |
15 | E | Compressor enable from DME | DME control unit |
16 | A | Supply, A/C pressure sensor | Coolant pressure sensor |
17 | E | Pressure sensor signal, air conditioning system | Coolant pressure sensor |
18 | M | Ground | Coolant pressure sensor |
19 | A | AUC heating supply | AUC sensor |
20 | A | AUC sensor supply | AUC sensor |
21 | E | AUC sensor signal | AUC sensor |
22 | M | AUC heater ground | AUC sensor |
23 | Not used | ||
24 | Not used | ||
25 | Not used | ||
26 | Not used | ||
Pin | Type | Description / Signal type | Connection / Measuring notes |
---|---|---|---|
1 | A | Supply, MI-bus motors | Stepper motors |
2 | E | Ground, MI-bus motors | Stepper motors |
3 | E/A | MI-bus | Stepper motors |
4 | A | Blower control voltage | Blower output stage |
5 | E | Evaporator temperature sensor | Evaporator temperature sensor |
6 | M | Sensor ground, air conditioning system | Evaporator temperature sensor |
7 | E | Bi-directional data interface | Mixed air temperature sensor |
8 | M | Sensor ground, air conditioning system | Mixed air temperature sensor |
9 | Not used | ||
10 | Not used | ||
11 | Not used | ||
12 | Not used | ||
13 | A | Signal, fresh air/recirculating air flap actuator | Fresh air/recirculating air flap motor |
14 | M | Ground signal, fresh air/recirculating air flap actuator | Fresh air/recirculating air flap motor |
15 | A | Signal, fresh air/recirculating air flap actuator | Fresh air/recirculating air flap motor |
16 | M | Ground signal, fresh air/recirculating air flap actuator | Fresh air/recirculating air flap motor |
17 | Not used | ||
18 | Not used | ||