A11a Heating/air conditioning system

Plug connector overview

NumberX-pin, colourDescription
X61026-pin, bluePlug connector Heating/air conditioning system
X471418-pin, bluePlug connector Heating/air conditioning system

Pin assignments at plug connector X610

PinTypeDescription / Signal typeConnection /
Measuring notes
1ETerminal 30Fuse F39
   
2ETerminal 15Fuse F22
   
3ETerminal 58gLight switch cluster
   
4MGroundGround connector
   
5 Not used 
   
6ASignal, auxiliary water pump Not M54Auxiliary water pump
   
7 Not used 
   
8ACompressor controlControl valve, refrigerant compressor
   
9E/AK-bus signalK-bus connector
   
10 Not used 
   
11 Not used 
   
12 Not used 
   
13ASignal, rear window defoggerRear defogger relay
   
14ASignal, rear window defoggerRear defogger relay
   
15ECompressor enable from DMEDME control unit
   
16ASupply, A/C pressure sensorCoolant pressure sensor
   
17EPressure sensor signal, air conditioning systemCoolant pressure sensor
   
18MGroundCoolant pressure sensor
   
19 Not used 
   
20 Not used 
   
21 Not used 
   
22 Not used 
   
23 Not used 
   
24 Not used 
   
25 Not used 
   
26 Not used 
   

Pin assignments at plug connector X4714

PinTypeDescription / Signal typeConnection /
Measuring notes
1ASupply, MI-bus motorsStepper motors
   
2EGround, MI-bus motorsStepper motors
   
3E/AMI-busStepper motors
   
4ABlower control voltageBlower output stage
   
5EEvaporator temperature sensorEvaporator temperature sensor
   
6MSensor ground, air conditioning systemEvaporator temperature sensor
   
7ESignal inputsMicroswitch, air distribution
   
8MSensor ground, air conditioning systemMicroswitch, air distribution
   
9 Not used 
   
10 Not used 
   
11 Not used 
   
12 Not used 
   
13ASignal, fresh air/recirculating air flap actuatorFresh air/recirculating air flap motor
   
14MGround signal, fresh air/recirculating air flap actuatorFresh air/recirculating air flap motor
   
15ASignal, fresh air/recirculating air flap actuatorFresh air/recirculating air flap motor
   
16MGround signal, fresh air/recirculating air flap actuatorFresh air/recirculating air flap motor
   
17 Not used 
   
18 Not used