Recording wakings
Difference between normal case A and failure frequent waking B (see illustration above).
- Terminal R OFF
- Waking FRM (8 minutes after terminal R Off): Consumer shutdown only if the vehicle is not locked.
- Waking instrument cluster (KOMBI) (40 minutes after terminal R Off): Query of the coolant temperature. Waking does not always occur, only under certain conditions.
- Waking instrument cluster (KOMBI) (80 minutes after terminal R Off): Query of the coolant temperature. Waking does not always occur, only under certain conditions.
- Authorised wakings: see table above.
In the event of frequent failure of bus waking, various causes are possible:
- Defective peripherals of the cause (for example defective sensor or switch).
- Defective control unit.
- Wake-up cable for causes connected to the PT-CAN (for example, loose contact).