The following values are assessed in the VANOS system test:
Value |
Value range |
Setpoint |
Minimum limit position of intake |
40-160 |
67-77 |
Maximum limit position of intake |
40-160 |
125-135 |
Minimum limit position of exhaust |
40-160 |
76-86 |
Maximum limit position of exhaust |
40-160 |
123-134 |
Adjusting time, spread too small |
0-2550 |
< 500 |
Adjusting time, spread too large |
0-2550 |
< 500 |