A11 Heating and A/C control module IHKR

Connector overview

NumberX-number of pinsDescription
X183413Heating and A/C control module Connector 0
X61026Heating and A/C control module Connector 3
X61118Heating and A/C control module Connector 4
X181533Heating and A/C control module Connector 5

Pin assignments at connector 0 X18341

PinTypeDescription / Signal typeConnection /
Measuring notes
1AMagnetic clutch voltage supplyHigh pressure switch
   
2ETerminal 30 voltage supplyFuse F11
   
3MGroundGround point
   

Pin assignments at connector 3 X610

PinTypeDescription / Signal typeConnection /
Measuring notes
1EVoltage supply, terminal 15Fuse F20
Battery voltage  
2ECompressor ON signal from engine control module (DME)Engine control module (DME)DDE control module
   
3AA/C compressor signal to engine control module (DME)Engine control module (DME)DDE control module
   
4AA/C standby signal to engine control module (DME)Engine control module (DME) 728i,730i, 735i, 740iDDE control module 725tds
  A/C splice 750i
5ARear window defogger relay controlRear defogger relay
   
6AFront defogger/washer jets relay controlFront defogger/washer jets relay
   
7 Not used 
   
8Aup to 08/1995 Not used as of 09/1995 Blower control voltageFinal stage unit
   
9 Not used 
   
10 Not used 
   
11 Not used 
   
12EConsumer cut-off signal83Y57Y83Y46Y83Y6cY83Y89Y83Y8bY83Y82Y83Y57Y83Y85Y81Y5bY83Y8b
   
13 Not used 
   
14AAuxiliary water pump controlAuxiliary water pump
   
15ABlower relay controlBlower relay
   
16 Not used 
   
17AAuxiliary fan normal speed relay controlAuxiliary fan normal speed relay
   
18ENighttime illumination signalLight module
   
19E/AK-bus signal lineK-bus splice
   
20ALeft water valve controlWater valve assembly, Left valve
   
21ARight water valve controlWater valve assembly, Right valve
   
22 Not used 
   
23 Not used 
   
24 Not used 
   
25 Not used 
   
26 Not used 
   

Pin assignments at connector 4 X611

PinTypeDescription / Signal typeConnection /
Measuring notes
1AActuating signalFresh air flap motor
   
2AActuating signalFresh air flap motor
   
3AActuating signalFresh air flap motor
   
4AActuating signalFresh air flap motor
   
5 Not used 
   
6 Not used 
   
7 Not used 
   
8 Not used 
   
9 Not used 
   
10AActuating signalRight ventilation flap motor
   
11AActuating signalRight ventilation flap motor
   
12AActuating signalRight ventilation flap motor
   
13AActuating signalRight ventilation flap motor
   
14MComponent groundSensor
   
15ESensor signalEvaporator temperature sensor
   
16ESensor signalRH heat exchanger temperature sensor
   
17ESensor signalLH heat exchanger temperature sensor
   
18ESwitch-off signalMotor limit switch
   

Pin assignments at connector 5 X18153

PinTypeDescription / Signal typeConnection /
Measuring notes
1APark heating ON signalup to 08/1995 Park heating/ventilation control module as of 09/1995 Receiver, independent heating
   
2AControl voltagePark heating relay
   
3EPark heating ON feedback signalPark heating/ventilation control module