Pin | Type | Description / Signal type | Connection / Measuring notes |
---|
1 | E | Voltage supply, terminal 15 | Fuse F20 |
| | |
2 | | Not used | |
| | |
3 | E/A | K-bus signal line | K-bus splice |
| | |
4 | E | Consumer cut-off signal | Consumer cut-off splice |
| | |
5 | A | Left water valve control | Water valve assembly Left valve |
| | |
6 | A | Right water valve control | Water valve assembly Right valve |
| | |
7 | A | Relay control Rear defogger relay | Rear defogger relay |
| | |
8 | A | Signal Heated washer jets | Connector, heated washer jets |
| | |
9 | A | Auxiliary water pump control with park heating, Auxiliary water pump control with latent heat accumulator | Auxiliary water pump with park heating, Connector, auxiliary water pump with latent heat accumulator |
| | |
10 | E | Pressure signal | High pressure switch |
| | |
11 | | Not used | |
| | |
12 | E | Signal input | Automatic air recirculation sensor |
| | |
13 | A | Voltage control | Automatic air recirculation sensor |
| | |
14 | | Not used | |
| | |
15 | A | A/C system standby signal | DDE control module |
| | |
16 | A | Signal, A/C compressor ON (M51) | DDE control module |
| | |
17 | A | Signal, A/C compressor OFF (M51) A/C compressor signal | DDE control module Engine control module (DME) Digital diesel electronics control unit |
| | |
18 | E | Auxiliary fan normal speed relay control | Connector, auxiliary fan stage 1 |
| | |
19 | | Not used | |
| | |
20 | M | Ground High pressure switch | High pressure switch |
| | |
21 | A | Power High pressure switch | High pressure switch |
| | |
22 | A | Shut-down signal with latent heat accumulator: | Connector, auxiliary water pump with latent heat accumulator: |
| | |
23 | E | Nighttime illumination signal | Terminal 58g splice |
| | |
24 | | Not used | |
| | |
25 | M | Ground AUC sensor, heating | Automatic air recirculation sensor |
| | |
26 | A | Voltage control AUC sensor, heating | Automatic air recirculation sensor |
| | |
Pin | Type | Description / Signal type | Connection / Measuring notes |
---|
1 | A | Sensor signal | LH heat exchanger temperature sensor |
| | |
2 | A | Sensor signal | RH heat exchanger temperature sensor |
| | |
3 | A | Sensor signal | Evaporator temperature sensor |
| | |
4 | A | Signal Final stage unit | Final stage unit |
| | |
5 | A | Signal Rear mixing actuator | Rear mixing actuator |
| | |
6 | M | Sensor ground | Sensor connector |
| | |
7 | E | Actuating signal Fresh air flap motor | Fresh air flap motor |
| | |
8 | A | Actuating signal Fresh air flap motor | Fresh air flap motor |
| | |
9 | A | Actuating signal Fresh air flap motor | Fresh air flap motor |
| | |
10 | E | Actuating signal Fresh air flap motor | Fresh air flap motor |
| | |
11 | A | Signal Rear mixing actuator | Rear mixing actuator |
| | |
12 | | Not used | |
| | |
Pin | Type | Description / Signal type | Connection / Measuring notes |
---|
1 | A | Relay control Relay for latent heat accumulator | Relay for latent heat accumulator |
| | |
2 | A | Park heating ON signal Valve control Changeover valve LWS | Park heating relay Changeover valve LWS |
| | |
3 | A | Park heating ON feedback signal | Independent park/auxiliary heating |
| | |
4 | A | Sensor signal | NTC resistor, steering angle sensor |
| | |
5 | M | Sensor ground | NTC resistor, steering angle sensor |
| | |
6 | A | Valve control Shutoff valve LWS | Shutoff valve LWS |
| | |