A14 Independent park/auxiliary heating

Connector overview

NumberX-pin, colorDescription
X6422-pin, BlackConnector Independent park/auxiliary heating
X7646-pin, BlackConnector Independent park/auxiliary heating
X010112-pin, BlackConnector Flame monitor
X010122-pin, BlackConnector Circulation pump motor
X010132-pin, BlackConnector Combustion-air blower motor
X010142-pin, BlackConnector Heater plug

Pin assignments at connector X642

PinTypeDescription / Signal typeConnection /
Measuring notes
1ETerminal 30Fuse F47
   
2MGroundGround point
   

Pin assignments at connector X764

PinTypeDescription / Signal typeConnection /
Measuring notes
1EPark heating ON signalReceiver, independent heating M57 Heating and A/C control module
   
2E/ADiagnostic signal TXD X183Splice, TXD X183
   
3 Not used 
   
4ETelestart signalHeating and A/C control module
   
5 Not used 
   
6APower Park heating metering pumpPark heating metering pump
   

Pin assignments at connector X01011

PinTypeDescription / Signal typeConnection /
Measuring notes
1APower Flame monitorFlame monitor
   
2ESignal Flame monitorFlame monitor
   

Pin assignments at connector X01012

PinTypeDescription / Signal typeConnection /
Measuring notes
1APower Circulation pump motorCirculation pump motor
   
2MGround Circulation pump motorCirculation pump motor
   

Pin assignments at connector X01013

PinTypeDescription / Signal typeConnection /
Measuring notes
1APower Combustion-air blower motorCombustion-air blower motor
   
2MGround Combustion-air blower motorCombustion-air blower motor
   

Pin assignments at connector X01014

PinTypeDescription / Signal typeConnection /
Measuring notes
1APower Heater plugHeater plug
   
2MGround Heater plugHeater plug