Pin | Type | Description / Signal type | Connection / Measuring notes |
---|
1 | M | Ground | Ground splice |
| | |
2 | E/A | K-bus signal line | K-bus splice |
| | |
3 | E | Pressure signal | High pressure switch |
| | |
4 | M | Ground High pressure switch | High pressure switch |
| | |
5 | A | Power High pressure switch 5 V stabilized | High pressure switch |
| | |
6 | E | Nighttime illumination signal | Terminal 58g splice |
| | |
7 | | Not used | |
| | |
8 | | Not used | |
| | |
9 | | Not used | |
| | |
10 | E | Voltage supply, terminal 15 | Fuse F19 |
| | |
11 | E | Consumer cut-off signal | Consumer cut-off splice |
| | |
12 | | Not used | |
| | |
13 | M | Blower control, stage 4/defrost | Relay, defrost |
| | |
14 | A | Relay control Rear defogger relay | Rear defogger relay |
| | |
15 | A | Auxiliary water pump control | Auxiliary water pump |
| | |
16 | A | Activation, water valve | Water valve assembly |
| | |
17 | | Not used | |
| | |
18 | E | Throttle actuator terminal 30 voltage supply | Fuse F6 |
| | |
Pin | Type | Description / Signal type | Connection / Measuring notes |
---|
1 | | Not used | |
| | |
2 | | Not used | |
| | |
3 | | Not used | |
| | |
4 | A | Sensor signal Evaporator temperature sensor | Evaporator temperature sensor |
| | |
5 | E | Sensor ground Evaporator temperature sensor | Evaporator temperature sensor |
| | |
6 | E | Signal, blower switch stage 0 (blower OFF) | Blower switch |
| | |
7 | E | Actuating signal Fresh air flap motor | Fresh air flap motor |
| | |
8 | A | Actuating signal Fresh air flap motor | Fresh air flap motor |
| | |
9 | A | Actuating signal Fresh air flap motor | Fresh air flap motor |
| | |
10 | E | Actuating signal Fresh air flap motor | Fresh air flap motor |
| | |
11 | | Not used | |
| | |
12 | | Not used | |
| | |