Measurement values DDE 6.0

 

Function

This service function can be used to read out the measurement values blocks from the DDE control module. The table below briefly describes the measurement values and provides notes on their interpretation.

Note: To continue the targeted diagnosis of certain components, the test modules for the corresponding functions and component groups must be used.

Measured value

Description

Remarks

Unit

Engine speed

Engine speed

 

rpm

Accelerator pedal module

Position of the accelerator pedal module, potentiometer 1

 

%

Coolant temperature

Coolant temperature

 

°C

Vehicle voltage

Voltage supply at the DDE control module

 

V

Status synchronization

Status of synchronization of camshaft and crankshaft sensors

relevant for engine startup

-

Ambient pressure

Ambient pressure

 

mbar

Alternator load signal

Load on the alternator

 

%

Kilometer reading

Kilometer reading

 

km

Injection volume

Injection rate calculated by DDE control module

 

mg/stroke

Air mass, actual

Air mass measured by HFM

 

mg/stroke

Air mass, nominal

nominal value of air mass calculated by DDE control module for EGR control

only relevant with active EGR control!

See functional description for EGR control

mg/stroke

Activation of EGR valve

Pulse duty factor the DDE control module uses to activate the EGR valve

 

%

Charge-air pressure, actual

Charge-air pressure measured by charge-air pressure sensor

 

mbar

Charge-air pressure, nominal

nominal charge-air pressure calculated by DDE control module for charge-air-pressure control

only relevant with active charge-air pressure control!

See functional description 'Charge-air pressure controller'

mbar

Rail pressure, actual

Rail pressure measured by rail-pressure sensor

 

bar (kPa/psi)

Rail pressure, nominal

nominal rail pressure calculated by DDE control module for rail pressure control

only relevant in the case of active rail pressure control, i.e. only with the engine running!

bar (kPa/psi)

Activation of pressure control valve

Pulse duty factor the DDE control module uses to activate the pressure control valve

 

%

Activation of flow regulating valve

Pulse duty factor the DDE control module uses to activate the flow regulating valve

 

%