The BYTEFLIGHT bus system has a star-shaped structure. The individual satellites (= control modules with/without sensors) are interconnected across a star connector by means of fiber-optic cables. The star connector in the BYTEFLIGHT bus system is the Safety and Gateway Module. There is a transmission and a reception module (transmitter and receiver) as a unit in each satellite for connecting to the BYTEFLIGHT bus. The unit has an integrated transmit and receive diode.
The procedure for the following fault memory entries is shown below:
Two cases are distinguished:
The following Table 1 shows which control modules generate a fault memory entry if a transmitting control module does not send a certain message. The first vertical column contains the transmitting control modules (TCU); the first horizontal line contains the receiving control modules (RCU).
Table 1:
|
RCU |
SBSL |
SBSR |
SFZ |
SGM |
TMFA |
TMBF |
SZL |
TCU |
|
|
|
|
|
|
|
|
SGM |
|
X |
X |
|
|
|
|
|
SBSL |
|
|
X |
X |
X |
X |
X |
X |
SBSR |
|
X |
|
X |
X |
X |
X |
X |
SFZ or TMFA or TMBF |
|
X |
X |
|
X |
|
|
|
Table 2:
|
RCU |
SBSL |
SBSR |
SFZ |
SGM |
TMFA |
TMBF |
SZL |
TCU = ? |
|
X |
X |
|
|
|
|
|
SBSL |
Satellite, B-pillar left |
SBSR |
Satellite, B-pillar right |
SFZ |
Satellite, vehicle center |
SGM |
Safety and Gateway Module |
TMFA |
Door module, driver |
TMBF |
Door module, passenger |
SZL |
Steering column switch cluster |
All work on the airbags must be carried out with the battery disconnected!
Connect and disconnect all BYTEFLIGHT control modules, sensors and generators only with the battery disconnected!
If a fiber-optic cable on the BYTEFLIGHT bus has to be repaired, it must be borne in mind that there may only be one join in a fiber-optic cable. If there is already a join due to a door connector, the fiber-optic cable must not be repaired. In the case of a defect, the fiber-optic cable must be replaced!