Unfavorable customer behavior with vehicle faults is a possible cause of breakdowns due to a depleted battery. In detail, the following individual causes can be determined:
If the vehicle does not reach the idle state after terminal R Off, i.e. the bus systems remain active, the causing control module is normally determined by the energy diagnosis.
The troubleshooting must be continued in the peripherals (e.g. defective sensor or switch) of each control module. If no fault is determined, replace the control module.
If a number of control modules on the PT CAN bus with the same kilometre reading are entered as cause in the energy history memory (e.g. EKP, DSC and SZL on diesel model or DME, DSC and SZL on vehicles with petrol engines), the wake-up line should be checked:
Important! Operation by the customer can also lead to an entry in some control modules: e.g. for E60-E61-E63-E64 e.g. listening to the radio with terminal R OFF leads to the registration of CID and M-ASK with the same kilometre reading as cause in the energy history memory.
If the vehicle keeps being woken up, the bus system causing the waking is determined by the energy diagnosis.
The causing control module cannot be determined automatically: Identify the possible cause by disconnecting fuses or disconnecting the corresponding control modules step by step.
If it was possible to determine the waking control module, troubleshooting must then be continued in the peripherals (e.g. defective sensor or switch, loose contact) of the control module. If no fault is determined, the control module must be replaced.
Note: In exceptional cases, it is possible that the result ”Vehicle keeps being woken up” is generated by unfavorable customer behavior. (E.g. frequently waking of the vehicle at terminal R off by opening and closing the luggage compartment lid or doors.)
The result ”Excessive closed-circuit current” means that the vehicle, occasionally at least, has had a closed-circuit current greater than 80 mA. Here, the vehicle was in the idle state, that is, the bus systems were inactive.
A possible cause of this could be defective control modules. As troubleshooting, run a closed-circuit current measurement and identify possible causes by disconnecting fuses or disconnecting the corresponding control modules step by step.
Procedure for external closed-circuit current measurement: see Service Information number 61039947.
Even though the battery was not the cause of the complaint, it might have been damaged beforehand due to deep discharge for a longer period. For this reason, check the battery condition if you suspect that the battery might have been damaged beforehand.
See ”Master document, battery” BMW Service Technology:
TIS -> Document -> Service Information -> Enter Number
SI number: 610702875
If there is a suspicion that the alternator is defective, it must be determined whether the DME/DDE has relevant fault memory entries. Fault memory entries with regard to the IBS must also be taken into account.
If the vehicle comes to a standstill and will not start during or shortly after a journey, the cause probably lies in the charge balance of the generator. A requirement here is that the charged battery was still able to deliver adequate current for the starting operation.