Signals in message invalid
In the control module network, important information is transferred across the bus for the function of the control module:
- Message faults
are saved if the communication across the bus (e.g.: CAN bus) is disrupted (e.g.: time-out).
- Signal faults
are saved when communication across the CAN bus is generally OK, but the transmitting control module cannot send a value and therefore sends a substitute value (default value).
Example:
The DSC can only send a valid speed signal for a wheel-speed sensor if this is OK. If the wheel-speed sensor is not OK, the DSC sends a defined substitute value (default value). The receiving control module (e.g.: Digital Diesel Electronics) detects on the basis of the substitute value that the bus communication is OK. The function of the Diesel Electronics, however, might be restricted and for this reason a signal fault is saved in the Diesel Electronics.
If signal faults are detected, they are assigned to the causing control module. Troubleshooting is then to be continued in the sending control module.
Speed signal invalid
The speed signal transferred via the CAN bus is monitored by the DDE control module as regards its validity and value.
In the event of a fault in the speed signal, troubleshooting must be continued at the sending control module.