Checking the 'roof package stored' sensor

Repair instruction for checking the 'roof package stored' sensor

Check whether the metal tab is stuck or bent at the 'roof package stored' Hall sensor.

The metal tab of the Hall sensor is visible when you look into the cone of the cover of the sensor from above.

  1. Carefully insert your finger from below into the cover of the 'roof package stored' Hall sensor. See Fig. 1.
  2. A metal tab is fitted under the cover and you can move this towards the rear with your finger. See Fig. 1. When you let go, the metal tab springs back to its initial position.
  3. If the metal tab is blocked by the sensor cable, clip the cable back into the bracket on the housing correctly.
  4. If the metal tab is difficult to move or is bent, the sensor must be replaced.

Image 1

GR_FB5407044

It must be possible to move the metal tab towards the rear (1) with your finger.